我得機器配置dell6400,adaptec的perc2 raid 卡,外加一個dell 221的陣列,機器內部8塊
73G硬盤,外部14塊73G硬盤,總容量1T多,系統sol2.7x86,perc2的raid卡化了22個
container,solaris2.7只能認識8個lun,郁悶。。。。。
手動修改/kernel/drv/sd.conf文件,一個lun只支持15個target,不用多寫,具體修改如下
# more /kernel/drv/sd.conf
#
# ident "@(#)sd.conf 1.17 98/08/10 SMI"
#
# Copyright (c) 1998 by Sun Microsystems, Inc.
# All rights reserved.
#
name="sd" class="scsi" target=0 lun=0;
name="sd" class="scsi" target=1 lun=0;
name="sd" class="scsi" target=2 lun=0;
name="sd" class="scsi" target=3 lun=0;
name="sd" class="scsi" target=4 lun=0;
name="sd" class="scsi" target=5 lun=0;
name="sd" class="scsi" target=6 lun=0;
name="sd" class="scsi" target=7 lun=0;
name="sd" class="scsi" target=8 lun=0;
name="sd" class="scsi" target=9 lun=0;
name="sd" class="scsi" target=10 lun=0;
name="sd" class="scsi" target=11 lun=0;
name="sd" class="scsi" target=12 lun=0;
name="sd" class="scsi" target=13 lun=0;
name="sd" class="scsi" target=14 lun=0;
name="sd" class="scsi" target=15 lun=0;
name="sd" class="scsi" target=0 lun=1;
name="sd" class="scsi" target=1 lun=1;
name="sd" class="scsi" target=2 lun=1;
name="sd" class="scsi" target=3 lun=1;
name="sd" class="scsi" target=4 lun=1;
name="sd" class="scsi" target=5 lun=1;
name="sd" class="scsi" target=6 lun=1;
name="sd" class="scsi" target=7 lun=1;
name="sd" class="scsi" target=8 lun=1;
name="sd" class="scsi" target=9 lun=1;
name="sd" class="scsi" target=10 lun=1;
name="sd" class="scsi" target=11 lun=1;
name="sd" class="scsi" target=12 lun=1;
name="sd" class="scsi" target=13 lun=1;
name="sd" class="scsi" target=14 lun=1;
name="sd" class="scsi" target=15 lun=1;
name="sd" class="scsi" target=0 lun=2;
name="sd" class="scsi" target=1 lun=2;
name="sd" class="scsi" target=2 lun=2;
name="sd" class="scsi" target=3 lun=2;
name="sd" class="scsi" target=4 lun=2;
name="sd" class="scsi" target=5 lun=2;
name="sd" class="scsi" target=6 lun=2;
name="sd" class="scsi" target=7 lun=2;
name="sd" class="scsi" target=0 lun=3;
name="sd" class="scsi" target=1 lun=3;
name="sd" class="scsi" target=2 lun=3;
name="sd" class="scsi" target=3 lun=3;
name="sd" class="scsi" target=4 lun=3;
name="sd" class="scsi" target=5 lun=3;
name="sd" class="scsi" target=6 lun=3;
name="sd" class="scsi" target=7 lun=3;
name="sd" parent="blogic" target=0 lun=0;
name="sd" parent="blogic" target=1 lun=0;
name="sd" parent="blogic" target=2 lun=0;
name="sd" parent="blogic" target=3 lun=0;
name="sd" parent="blogic" target=4 lun=0;
name="sd" parent="blogic" target=5 lun=0;
name="sd" parent="blogic" target=6 lun=0;
name="sd" parent="flashpt" target=0 lun=0;
name="sd" parent="flashpt" target=1 lun=0;
name="sd" parent="flashpt" target=2 lun=0;
name="sd" parent="flashpt" target=3 lun=0;
name="sd" parent="flashpt" target=4 lun=0;
name="sd" parent="flashpt" target=5 lun=0;
name="sd" parent="flashpt" target=6 lun=0;
touch /reconfigure
reboot
然後認到了22個container,好像sun的網站提供sd.conf文件的補丁,我試了,但是不行
sparc的機器也會有此問題,解決如下
8 LUNS with Solaris 2.7/E250/A1000/RAID 6.1.1 Update 2
Thanks to Andreas Sinderman (who responded immediately to the ssa-managers
mail) and Mark Reid at Sun (who responded to my service call).
Andreas had it mostly right. The Tpatch (T106925-03) coupled with the other
required configuration file changes fixed things (I got the Tpatch from Mark).
Solaris 7 doesn't support more than 16 LUNS.
In addition to the Tpatch, you need to have the following:
* Appropriate entries in /kernel/drv/sd.conf -- manually type them in (like
I did) or run add16luns.sh from the Tools directory on the Raid Manager
software cd.
* create/edit /kernel/drv/glm.conf to have:
device-type-scsi-options-list =
"Symbios StorEDGE A1000", "lsi-scsi-options",
"Symbios StorEDGE A3000", "lsi-scsi-options",
"SYMBIOS RSM Array 2000", "lsi-scsi-options";
lsi-scsi-options = 0x407f8;
* change the /etc/osa/rmparams to have 16 MaxLuns instead of 8:
System_MaxLunsPerController=16
All this and boot -r. I found that the /dev/dsk links for disks 8 and up were
not created at boot time, but were created as LUNS using these disk numbers
were created.
lauradel
我沒有測試過,如果可以,請告訴大家方法吧